Installing ControlaSola

Choose your supply and loads to see how the wiring fits your home.

Electrician only. This page is a general guide. Installation must be done by a qualified, licensed electrician in line with AS/NZS 3000 (the Wiring Rules) and your state requirements. Isolate and test every circuit before opening the switchboard or the device. Switching off one breaker does not isolate the others, because each load has its own supply wire.
Your supply
Loads

Three-phase, hot water 1, hot water 2 and pool

SWITCHBOARDIncoming supply from meter / gridL1CT1L2CT2L3CT3Neutral barEarth barControlaSola(solid-state switches inside)CT1CT2CT3Power and controlneutral in, live from HW1Neutral: direct to each load, plus one to the deviceEarth: direct to each loadHW1breakerHW1 SSRHW1 inoutactiveHot water 1ANEHW2breakerHW2 SSRHW2 inoutactiveHot water 2(optional)ANEPoolbreakerPool SSRPool inoutactivePool pump(optional)ANE
Active (live)NeutralEarthCT lead (low voltage signal)Internal to the device

Wires that cross without a dot are not connected. Which phase feeds which load is an example only. Neutral from the grid to the neutral bar is not shown.

How it is wired

  • The device acts as a switch in the active (live) wire of each load. The solid-state relays are built in.
  • Each load gets its own active wire from its breaker to the device, and another from the device to the load. This is true on single-phase too.
  • Neutral and earth do not go through the device. They run directly from the switchboard bars to each load.
  • The device needs a neutral to power itself. It needs no separate active: it takes its power internally from the hot water 1 active.
  • Three CTs clamp the incoming phase conductors (L1, L2, L3) at the grid connection and connect to CT1, CT2 and CT3. Keep the CT numbers matched to the phases, and fit each CT in the direction marked on it.
  • One CT clamps the incoming active conductor at the grid connection and connects to CT1. Fit it in the direction marked on the CT.

What connects where

ConnectionFromTo
Hot water 1 activeHW1 breakerDevice HW1 in, then out to the hot water 1 element
Hot water 2 activeHW2 breakerDevice HW2 in, then out to the hot water 2 element
Pool activePool breakerDevice pool in, then out to the pool pump
Neutral to each loadNeutral barDirectly to each load, not through the device
Earth to each loadEarth barDirectly to each load, not through the device
Neutral for the deviceNeutral barDevice N terminal
CT leadsCTs on L1, L2, L3Device CT1, CT2, CT3
CT leadCT on the incoming activeDevice CT1

Installation steps

  1. Switch off at the main switch and prove every circuit dead.
  2. Mount the device near the switchboard.
  3. Fit the three CTs on the incoming phase conductors and connect them to CT1, CT2 and CT3.
  4. Fit the CT on the incoming active conductor and connect it to CT1.
  5. Run the hot water 1 active from its breaker to the device HW1 in terminal, and from the device HW1 out terminal to the hot water 1 element.
  6. Do the same for hot water 2, with its own breaker and its own wires.
  7. Do the same for the pool pump, with its own breaker and its own wires.
  8. Connect neutral and earth from the switchboard bars directly to each load.
  9. Connect one neutral from the neutral bar to the device N terminal.
  10. Close up the switchboard, restore power and test.

Things to know before you start

  • The device is powered from the HW1 active. If the hot water 1 breaker is off or tripped, the device is off and cannot control the other loads either.
  • Each load keeps its own protection. Every load circuit needs its own breaker and any RCD protection required by the wiring rules.
  • Controlled-load (off-peak) hot water: if a hot water system is on a controlled-load circuit with its own meter or relay, speak to your electrician and electricity retailer first. The circuit has to be live during the day for solar heating to work.
  • CT leads carry low-voltage signals. Keep them tidy and away from mains cables where practical.
  • The diagrams show the general arrangement. They do not replace the instructions that come with your device.

After installation

  1. Power up. When the device connects to the internet, your Device ID appears on its display.
  2. Register on this website and enter your Device ID.
  3. Log in and work through the My Device settings: tariffs, hot water times and pool run times.
  4. Open My Device Compare to see your results.

Questions about your installation?

Send us your switchboard photos and set-up details and we will help your electrician.